فیلترها/جستجو در نتایج    

فیلترها

سال

بانک‌ها




گروه تخصصی











متن کامل


اطلاعات دوره: 
  • سال: 

    2009
  • دوره: 

    3
  • شماره: 

    SUPPLEMENT 1 (12TH INTERNATIONAL CONGRESS OF NEPHROLOGY, DIALYSIS, AND TRANSPLANTATION)
  • صفحات: 

    92-92
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    218
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

Introduction. Urea pharmacokinetic equation systems have contributed to better understanding of the treatment dose among hemodialysis patients. The normalized treatment ratio, Kt/V assumes that smaller patients with low volume of urea distribution (V) require proportionately less total treatment (Kt) than bigger patients. Our aim was to compare estimates of dialysis adequacy obtained by single-pool Kt/V (spKt/V) and Surface-Area-Normalized Kt/V (SAN-Kt/V) formulas, and to identify the similarities and differences between these estimates.Methods. Study was carried out on 46 patients. A stable dialysis schedule was maintained during the study. SpKt/V and SAN-Kt/V were calculated from urea estimations using the following formulas: spKt/V = -ln(R - 0.008 x t) + (4 - 3.5 x R) x UF/W, where R is the Ct/Co, t is the duration of the HD session, UF is the ultrafiltration volume, and W is the body weight after the HD session. SAN-Kt/V = spKt/V multiplied by Vant/(3.271 x Vant2/3; in females, multiplied again by 0.91). Dialysis dose with the Kt was also measured in each session. Results. A total of 46 patients with mean age of 45.84 ±17.29 were included. Of them, 25 (54.34%) were male and 21(45.62%) were famale. With a prescribed mean Kt of 44.13 ± 2.66 lit, Sp Kt/v and SAN-Kt/v were more than 1.2 in 50% and 43.5% of the patients, respectively. According to sex, despite statistically equal prescribed Kt (mean Kt was 44.11 ± 2.6 lit and 44.12 ±2.7 lit in male and female patients), Sp Kt/v was significantly higher in females (1.27 ± 0.23 vs 1.06 ± 0.25; P = 0.006). Surprisingly, SAN-Kt/v in both groups was not significant (in males: 1.10 ±0.24 and in females: 1.07 ±.23; P = 0.667). Body surface area of the dialyzed subject and Sp Kt/v showed negative correlation (r = -0.583, P < 0.001). Conclusion. With an equal prescribed dialysis dose, delivered Kt/v by single-pool Kt/v in females is significantly higher than males but by SAN Kt/v, the results are somehow equal which could be due to BSA normalization.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 218

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1391
  • دوره: 

    11
  • شماره: 

    1 (مسلسل 76)
  • صفحات: 

    43-48
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    8761
  • دانلود: 

    687
چکیده: 

زمینه و هدف: بیماران مبتلا به نارسایی مرحله پایانی کلیه، نیازمند دریافت دیالیز با کفایت کافی می باشند. بر اساس خط مشی های DOQI حداقل کفایت دیالیز به روش KT/V در بیماران همودیالیزی 1.2 یا بیشتر است. در این مطالعه، هدف ما تعیین کفایت دیالیز در بیماران همودیالیزی بیمارستان شهید بهشتی آبادان می باشد.روش بررسی: ما در مطالعه مقطعی و آینده نگر، در تابستان سال 1389 مقادیر KT/V بیماران همودیالیزی آبادان را ارزیابی نمودیم. همودیالیز به مدت 3 تا 4 ساعت با صافی سنتتیک و با مایع دیالیز بی کربناتی انجام می شد. بلافاصله قبل و بعد از هر دیالیز، نیتروژن اوره خون (BUN) اندازه گیری می شد. برای BUN بعد از دیالیز، سرعت جریان خون به 100 سی سی در دقیقه کاهش و پس از 15 ثانیه نمونه خون گرفته می شد. برای تخمین KT/V از درصد کاهش اوره (PRU) از فرمول زیر استفاده نمودیمKT/V=(0.026×PRU)-0.460 .یافته ها: 54 بیمار همودیالیزی (28 زن و 26 مرد) با سن متوسط 39±14.2 سال در مطالعه قرار داده شدند. شایع ترین علت ESRD فشار خون (24.07 درصد)، ناشناخته (22.22 درصد)، دیابت (18.51 درصد)، گلومرولونفریت مزمن (14.81 درصد)، انسداد مجاری ادراری (12.96 درصد) و بیماری کیستیک کلیه (7.40 درصد) بود. KT/V در 87 بیماران (74 نفر) کمتر از 1.2 محاسبه شد. تفاوت قابل توجهی میان مقدار KT/V در مرد و زن (P=0.57) و غلظت های مختلف هموگلوبین (P=0.58) وجود نداشت.نتیجه گیری: نتایج این مطالعه نشان داد که بیشتر بیماران همودیالیزی این مرکز، حداقل دوز دیالیز را دریافت ننموده اند و ما باید علل آن را ارزیابی و اصلاح نماییم.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 8761

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 687 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

DAUGIRDAS J.T.

اطلاعات دوره: 
  • سال: 

    1990
  • دوره: 

    36
  • شماره: 

    -
  • صفحات: 

    M362-M362
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    124
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 124

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1385
  • دوره: 

    64
  • شماره: 

    1
  • صفحات: 

    7-11
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    837
  • دانلود: 

    320
چکیده: 

زمینه و هدف: همودیالیز به عنوان یک روش renal replacement تراپی در بیماران مبتلا به نارسایی مزمن پیشرفته کلیه بکار می رود.از زمانیکه همودیالیز به عنوان روش درمانی بکار گرفته شد همواره کفایت آن مورد سوال بود. ما در این مطالعه بین دو روش کفایت دیالیز با استفاده از ure Kinetic modeling )محاسبه (deliverd dialysis با استفاده از پارامترهای آزمایشگاهی اوره و همودیالیز product (زمان و تعداد دفعات دیالیز) را بررسی کردیم.روش بررسی: این مطالعه به روش توصیفی تحلیلی انجام شد و پس از نمونه گیری اوره قبل و بعد از دیالیز و وزن قبل و بعد از دیالیز و تعداد دفعات و ساعت دیالیز در هفته محاسبه شده و با استفاده از فرمولهای موجود کفایت (KT/V) d و HDP مورد ارزیابی قرار گرفت.یافته ها: پس از آنالیز یافته های بدست آمده روی صد بیمار مورد مطالعه، %43 بیماران (KT/V) d>1، و (KT/V) d<1 %57 داشتند. HDP در افرادیکه (KT/V) d>1 داشتند >36 بود. بین (KT/V) d و Alb ارتباط معنی دار مشاهده شد. P<0.03)، (r=0.3. رابطه بین (KT/V) d با کلسترول، Hb و کراتینین معنی دار نبود که شاید علت مهم آن تغذیه بیماران باشد. بین (KT/V) d و HDP با P<0.001)، (r=0.4 ارتباط معنی دار مشاهده شد.نتیجه گیری: با افزایش ساعت و تعداد دفعات دیالیز می توان به (KT/V) d بالاتر دست یافت و کفایت دیالیز را بهبود بخشید.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 837

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 320 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    16
  • شماره: 

    5
  • صفحات: 

    304-310
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    42
  • دانلود: 

    0
چکیده: 

Introduction. The rates of morbidity and mortality in patients receiving routine hemodialysis have been demonstrated to be significantly affected by the dose of HD. As the national and international standards for determination of dialysis adequacy vary among countries, it is necessary to investigate the optimum criteria for HD adequacy. In this study, we aimed at comparing HD adequacy, through two methods of OCM with electrical conductance, and blood-driven Kt/V of urea, in the largest hemodialysis center in Iran. Methods. The value of UC, as an indicator of HD adequacy, was measured 301 times in 120 HD patients via two methods of OCM and blood-driven clearance of urea. For urea-driven Kt/V, two blood samples, each 2 milliliters, were taken from the patient, one before and one after a HD session. For OCM, Fresenius 4008 dialysis machine was set online once the patient was receiving HD. The results of these two methods were analyzed regarding the correlation with patients’,demographics, BMI, required weekly HD sessions, type of HD access, type of dialyzers, hematocrit, UDV, ultrafiltration, and blood flow rate. Results. The mean values of UC obtained from blood samples and OCM were almost similar and not significantly different (1. 20 vs. 1. 11, P =. 50). UC values, measured by laboratory assessments were significantly associated with gender, BMI and UDV, while UC values from OCM were significantly associated with gender, BMI, dialyzer type, UDV and ultrafiltration. Conclusions. We conclude that OCM can be used as an effective substitute for laboratory assessment in HD centers to assess HD adequacy.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 42

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2009
  • دوره: 

    3
  • شماره: 

    SUPPLEMENT 1 (12TH INTERNATIONAL CONGRESS OF NEPHROLOGY, DIALYSIS, AND TRANSPLANTATION)
  • صفحات: 

    89-89
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    240
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

Introduction. A central issue in the management of patients undergoing maintenance hemodialysis is the assessment of adequacy of dialysis. Simply, evaluating the blood urea nitrogen (BUN) is insufficient because a low BUN can reflect inadequate nutrition. In 2007, the mean delivered single pool KT/V of adult in-center dialysis patients in the United States was approximately above 1.5. By comparison, a survey of dialysis practices in the years 1998 to 2000 in five European countries found that the mean delivered Kt/V varied from 1.28 to 1.50. Methods. In this observational study, we have evaluated 35 patients’ files, between 2006 and 2008, in Al-Zahra hospital hemodialysis center. Our information sheets contained age, gender, underlying diseases, monthly URR and KT/V according to the Daugirdas II formula, calcium, phosphorus, parathyroid hormone (PTH), fasting blood sugar (FBS), hemoglobin, albumin, cholesterol, triglyceride, HDL, and LDL. Then, this information was expressed for frequency and descriptive parameters and analyzed by SPSS version 15.0 software.Results. There were 19 (54.3%) males and 16 (45.7%) females; their age ranged from 10 to 78 years. Diabetes was the most common known cause of ESRD in 8 (22.9%) followed by hypertension in 4 (11.4%); other etiologies were detected in 14 (40.0%) patients and in 9 (25.7%), the etiology was unknown. As it can be seen, the average URR and KT/V of our patients are in the recommended range.Conclusion. We conclude that our hemodialysis patients are under the worldwide recommended desired dialysis program. But, quality control and improvement of our services should always be our consideration.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 240

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
نویسندگان: 

DAUGIRDAS J.T.

اطلاعات دوره: 
  • سال: 

    1993
  • دوره: 

    4
  • شماره: 

    -
  • صفحات: 

    1205-1205
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    156
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 156

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1387
  • دوره: 

    3
  • شماره: 

    2
  • صفحات: 

    7-12
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    982
  • دانلود: 

    447
چکیده: 

مقدمه: این تحقیق با هدف تعیین رابطه کفایت دیالیز با دز اریتروپوئیتین مکمل تجویز شده در بیماران تحت درمان با همودیالیز شهرستان شاهرود انجام شده است.مواد و روش ها: نمونه های پژوهش شامل 54 بیمار تحت درمان با همودیالیز در شهرستان شاهرود بودند. معیار ورود نمونه شامل درمان با همودیالیز به مدت 6 ماه، درمان با اریتروپوئیتین زیر جلدی حداقل برای 4 ماه، فریتین پلاسمای بیش تر از 100 نانوگرم در میلی لیتر و هماتوکریت هدف 30% برای مدت 3 ماه بود. برای بررسی کفایت دیالیز انجام شده ضریب Kt/V برای بیماران محاسبه شده است.نتایج: در این مطالعه 30 نفر (55.6%) بیماران مذکر و 24 نفر (44.4%) مونث بودند. 70.4% بیماران (38 نفر) دارای ضریب Kt/V کم تر از 1.2 و 29.6% (16 نفر) دارای ضریب Kt/V بیش تر از 1.2 بودند. آزمون آماری t مستقل نشان دهنده عدم وجود اختلاف معنادار بین میزان آهن، فریتین، هموگلوبین و هماتوکریت در بیماران با Kt/V کم تر و بیش تر از 1.2 بود، اما بین میزان تزریق اریتروپوئیتین و ضریب Kt/V ارتباط معناداری مشاهده گردید، به طوری که میانگین تزریق ماهانه اریتروپوئیتین در بیماران با Kt/V>1.2 کم تر از میانگین آن در بیماران باKt/V<1.2  بود.نتیجه گیری: یافته های حاصل از این پژوهش و سایر پژوهش ها در زمینه تجویز اریتروپوئیتین در بیماران مبتلا به نارسایی مزمن کلیه تحت درمان با دیالیز مبین آن است که انجام دیالیز کافی Kt/V) بیش تر از 1.2) می تواند ضمن کاهش نیاز بیماران به اریتروپوئیتین مکمل و هزینه های ناشی از آن، سبب کاهش عوارض احتمالی این دارو نیز گردد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 982

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 447 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1387
  • دوره: 

    51
  • شماره: 

    99
  • صفحات: 

    45-52
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    3059
  • دانلود: 

    450
چکیده: 

مقدمه: دوز دیالیز موثر (dKt/V: delivered Kt/V)به عنوان یک عامل مهم در مرگ و میر بیماران دیالیزی شناخته شده است،که به دلایل نامشخص در بیشتر مراکز دیالیز به طور مرتب اندازه گیری نمی شود. در این مطالعه، در ابتدا dKt/V در بیماران دیالیزی تعیین و سپس عوامل موثربرکفایت دیالیز مورد بررسی قرار گرفته است.روش کار: این مطالعه توصیفی تحلیلی بر 48 بیمار همودیالیزی بیمارستان امام رضا (ع) مشهد در سال 1384 انجام شده است. در این مطالعه(dKt/V) در بیماران اندازه گیری شد و بیماران بر اساس آن به دو گروه با dKt³1.2 و 1.2>dKt/V تقسیم شدند. میزان ری سیرکولاسیون (AR: Access Recirculation)، وضعیت همودینامیک حین دیالیز، دوز اریتروپویتین هفتگی، فشارمنفی ( Negative Pressure:NP)، فشار وریدی (VP: Venous Pressure)، حجم توزیع اوره (V: Urea Distribution) وKt/V  تجویز شده (pKt/V: prescribed Kt/V)در بیماران ثبت و با استفاده ازروش های آماری وSPSS در دو گروه مقایسه شد.نتایج: در کل بیماران، 19 بیمار (39.6%) مذکر و 29 بیمار (60.4) مونث بودند. متوسطdKt/V در کل بیماران 1.05±0.36 بود، محدوده سنی بیماران بین 18 تا 72 سال بود. از 48 بیمار، 19 نفر (39.6%) dKt³1.2 و 29 بیمار (60.4) 1.2>dKt/V داشتند. میزان فراوانی AR بیشتر از 10 درصد، NPبیشتر از250،V بیشتر از60 و متوسط دوز اریتروپویتین در گروه با 1.2>dKt/V نسبت به dKt³1.2 بیشتر بود ولی بر اساس اطلاعات آماری در دو گروه اختلاف معنی داری مشاهده نشد. میانگینpKt/V در گروه های با dKt³1.2 و 1.2>dKt/Vبه ترتیب 1.44±0.25 و 1.22±0.25 بود که به لحاظ آماری در دو گروه تفاوت معنی دار وجود داشت (0.03=p).نتیجه گیری: این مطالعه نشان داد که بین عوامل موثر در عدم کفایت دیالیز، شامل دوز پایین دیالیز، عوامل مربوط به بیمار (افت فشار خون، علایم حین دیالیز) و عوامل تکنیکی (AR، NP)، مهم ترین عامل، تجویز ناکافی دوز دیالیز است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 3059

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 450 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1380
  • دوره: 

    5
  • شماره: 

    4 (مسلسل 20)
  • صفحات: 

    18-22
تعامل: 
  • استنادات: 

    3
  • بازدید: 

    1613
  • دانلود: 

    384
چکیده: 

مقدمه: بیماریهای قلبی- عروقی و عدم کفایت دیالیز اصلی‎ترین عوامل تعیین‏کننده ناتوانی و مرگ و میر در بیماران دیالیزی می‎باشد. بالا بردن کفایت دیالیز در پیش‎آگهی بیماران دیالیزی کاملاً مؤثر است. هدف از این مطالعه تعیین کفایت دیالیز در سه مرکز دیالیز در استان کردستان می‏باشد. مواد و روشها: جامعه آماری شامل کلیه بیماران دیالیزی است که در سه مرکز دیالیز در استان کردستان تحت دیالیز بودند. نوع مطالعه توصیفی تحلیلی (Cross-Sectional) بود. داده‎های لازم عبارت بودند از: وزن بیمار قبل از دیالیز، وزن بیمار بعد از دیالیز، اولترافیلتراسیون دستگاه، BUN قبل از دیالیز و BUN بعد از دیالیز. این داده‎ها از بیماران جمع‎آوری و در یک برگ چک لیست ثبت گردید و پس از ورود داده‎ها به کامپیوتر نسبت به محاسبه میزان کلیرانس اوره توسط دیالیز(Kt/V)1  و تجزیه و تحلیل داده‎ها اقدام شد. نتایج: نتایج مطالعه نشان داد که میانگین Kt/V در افراد مورد مطالعه 0.94با انحراف معیار 0.37بود. میانگین Kt/V در جنس زن 0.87و در جنس مرد 1.03بوده است و همچنین بالاترین میانگین Kt/V در مرکز سنندج با  Kt/V=1.16و کمترین آن در مرکز مریوان با Kt/V=0.95 بدست آمد. آزمون آماری آنالیز واریانس اختلاف میانگین مراکز مختلف استان کردستان را کاملاً معنی‎دار نشان می‎دهد. میانگین ساعات دیالیز در هفته در بیماران مورد مطالعه 9 ساعت با انحراف معیار 2.7 ساعت بود. نتایج این مطالعه رابطه بین ساعات دیالیز در هفته و میانگین Kt/V را معنی‏دار نشان نداد. نتیجه‎گیری: بر اساس نتایج این مطالعه مشخص شد که دیالیز انجام شده در مراکز دیالیز مذکور در استان کردستان کفایت لازم را ندارد. بنابراین لازم است مطالعات دیگری در زمینه علل عدم کفایت دیالیز در سطح استان کردستان انجام گیرد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1613

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 384 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 3 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button